          Document revision date: 30 March 2001
      
     | 
  
 
  
    
![[Compaq]](../images/compaq.gif)  | 
    
       
 
 
 
 
      
     | 
  
 
  
    
 
     | 
  
 
 
 
 
OpenVMS System Messages: Companion Guide for Help 
Message Users
Datagram Free Queue Insert Failure
Facility: Cluster Port Driver
Explanation: The port driver attempts to reinitialize 
the port; after 50 failed attempts, it marks the device off line. This 
error is caused by a failure to obtain access to an interlocked queue. 
Possible sources of the problem are CI hardware failures or memory, SBI 
(VAX-11/780), CMI (VAX-11/750), BI, PCI, or XMI contention.
User Action: Contact a Compaq support representative.
Datagram Free Queue Remove Failure
Facility: Cluster Port Driver
Explanation: The port driver attempts to reinitialize 
the port; after 50 failed attempts, it marks the device off line. This 
error is caused by a failure to obtain access to an interlocked queue. 
Possible sources of the problem are CI hardware failures or memory, SBI 
(VAX-11/780), CMI (VAX-11/750), BI, PCI, or XMI contention.
User Action: Contact a Compaq support representative.
DBLERR, double error halt restart
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable hardware error. Because of the severity of the error, 
further operation is impossible or it could corrupt user data. After 
all physical memory is written to a system dump file, the system 
automatically reboots if the BUGREBOOT system parameter is set to 1.
User Action: Thoroughly test all system hardware 
components. If no hardware errors are located and if the problem 
persists, note the conditions at the time of the error. Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DEADLOCK, deadlock detected
Facility: MOUNT, Mount Utility
Explanation: The first 12 characters of an ISO 9660 
CD-ROM's volume name and volume set name are the same. When an attempt 
is made to mount the volume, both names are used to construct an 
OpenVMS lock request to manage volumes within a volume set. However, if 
the first 12 characters of the names match, the lock request fails.
User Action: Mount the volume specifying a different 
volume set name.
DECPTREF, decrement page table reference count error
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DEFCLI, you are not authorized to specify CLI parameters
Facility: LOGIN, Login Procedure
Explanation: Authorization is needed to specify an 
alternate command language interpreter (CLI) or alternate CLI tables.
User Action: Log in again without specifying the /CLI 
or /TABLES qualifiers after your user name.
DELCONPFN, fatal error in delete contents of PFN
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DELETE, error deleting 'file-name' file ID ('numeric-string')
Facility: BACKUP, Backup Utility
Explanation: An error is encountered during an attempt 
to delete the file with the specified file identification in response 
to the /DELETE qualifier. The accompanying message provides additional 
information.
User Action: None.
DELETESWL, 'device-name' is write protected - file deletion pass not 
executed
Facility: BACKUP, Backup Utility
Explanation: The input device is software write 
locked. The Backup utility cannot perform the file deletion pass.
User Action: Dismount the input device, remount it 
writable, and either delete the files by hand or reenter the BACKUP 
command.
DELGBLSEC, delete global section error
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DELGBLWCB, delete global section window error
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DELPORT, deleted port 'port-name'
Facility: LAT, LAT Facility
Explanation: The specified port has been deleted by 
LATCP.
User Action: None.
DELSERVICE, deleted service 'service-name'
Facility: LAT, LAT Facility
Explanation: The specified service has been deleted by 
LATCP.
User Action: None.
DELWSLEX, delete working set list entry index error
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DENIGNORED, /DENSITY qualifier not appropriate to this device; ignored
Facility: MOUNT, Mount Utility
Explanation: The /DENSITY qualifier was supplied on 
the command line for a device that does not support various densities. 
The qualifier is ignored.
User Action: Omit the /DENSITY qualifier to avoid 
getting this system message. Use the /MEDIA_FORMAT=[NO]COMPACTION 
qualifier if the device supports compaction.
DENSITY, 'saveset-spec' does not support specified density - default 
used
Facility: BACKUP, Backup Utility
Explanation: The specified tape hardware does not 
support the density selected by the /DENSITY qualifier. The Backup 
utility uses the default density.
User Action: Use a different tape device, or specify a 
different density.
DEQSUBLCKS, tried to dequeue lock with sublocks
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DETSHADINCON, mount has detected an inconsistent state for shadowing
Facility: MOUNT, Mount Utility
Explanation: MOUNT has detected an internal 
inconsistency while attempting to mount a shadow set. This message 
indicates a failure in either MOUNT or the OpenVMS Volume Shadowing 
software.
User Action: Contact a Compaq support representative and provide as much 
detail as possible about the circumstances surrounding this error.
DEVBUSY, mount or dismount in progress on device
Facility: MOUNT, Mount Utility
Explanation: MOUNT has been retrying a mount operation 
for at least two minutes. The operation keeps failing because the 
master member of a shadow set is no longer valid, probably because a 
simultaneous dismount operation is being attempted on the set.
User Action: Ensure that no dismount operation is 
being performed on the set and attempt the mount operation again. If 
the operation continues to fail, contact a Compaq support representative.
DEVCOUNT, number of devices must match number of volumes
Facility: MOUNT, Mount Utility
Explanation: The number of devices specified in the 
DCL command MOUNT to mount a disk volume set does not match the number 
of volume labels specified in the command.
User Action: Verify the names of the devices and 
volume labels for the command and then reenter the command with a 
matching number of devices and volume labels.
DEVDMT, device is marked for dismount
Facility: MOUNT, Mount Utility
Explanation: The device is in the process of being 
dismounted. No mount requests can be processed on this device until the 
dismount completes. If this condition persists, files are open on the 
device.
User Action: Close any open files on the device. If 
other processes have open files, the system manager may need to resolve 
the situation.
DEVICES, only one device allowed
Facility: MOUNT, Mount Utility
Explanation: More than one device was specified in the 
DCL command MOUNT. Only one volume at a time can be mounted for this 
specified type of mount.
User Action: Reenter the DCL command MOUNT, specifying 
only one device.
DEVNOFE, device does not support FORCED ERROR handling. To override use 
the /OVERRIDE=NO_FORCED_ERROR qualifier
Facility: MOUNT, Mount Utility
Explanation: The device being mounted into a shadow 
set does not support forced error handling and the 
/OVERRIDE=NO_FORCED_ERROR qualifier was not specified.
User Action: Specify the /OVERRIDE=NO_FORCED_ERROR 
qualifier and retry the operation.
DEVNOTKNWN, device not known: 'input'
Facility: SYSGEN, System Generation Utility
Explanation: The specific device is unknown.
User Action: See the OpenVMS VAX Device Support Manual for the correct 
UNIBUS controller name.
DEVSHAMEM, device is already mounted as a shadow set member
Facility: MOUNT, Mount Utility
Explanation: The device you attempted to mount as a 
nonshadowed device is already mounted elsewhere in the cluster as a 
shadow set member.
User Action: Mount the device as a member of a shadow 
set. You can use DSA: to specify a generic virtual unit if you do not 
know which virtual unit contains the device.
DIAGPACK, 'disk' is a diagnostic pack
Facility: BACKUP, Backup Utility
Explanation: Either a Backup utility operation 
attempted to use a volume identified as a diagnostic volume, or the 
INITIALIZE command was used to initialize a diagnostic volume. In 
either case, the volume cannot be used.
User Action: Retry the operation using another volume.
DIFVOLMNT, different volume already mounted on this device
Facility: MOUNT, Mount Utility
Explanation: Previously, a different volume was 
mounted on this device on another node in the cluster. The device may 
be in mount verification on the other node. Either the original volume 
was removed from the device and replaced with another, or its volume 
identification was overwritten.
User Action: Restore the previously mounted volume to 
the device. If this is not possible, dismount the device on all nodes 
that currently have it mounted. Then retry the mount operation.
DIRENTRY, ACP failed to find same directory entry
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DISKCLASS, fatal error detected by Disk Class driver (DUDRIVER)
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DISKFRAG, free space on 'device-name' is too fragmented
Facility: BACKUP, Backup Utility
Explanation: The number of free extents on the 
specified volume is unreasonably large. The volume cannot be used as a 
save-set disk.
User Action: Reinitialize the volume, or select 
another volume and retry the operation.
DISMAL, all of the volumes have been dismounted
Facility: MOUNT, Mount Utility
Explanation: All of the volumes mounted by this 
invocation of $MOUNT or the MOUNT command have been dismounted because 
of errors that were detected after the volumes were mounted.
User Action: Take the action based on the preceding 
messages, and reenter the MOUNT command.
DISMOUNTD, volume 'volume-name' of volume-set 'volume-set-name' 
dismounted
Facility: MOUNT, Mount Utility
Explanation: The specified volume of the specified 
volume set has been dismounted because of errors encountered in 
processing the volume after it is mounted. An error with part of a 
volume set causes the entire volume set to be dismounted. This message 
appears for each member of the volume set that is dismounted due to the 
error condition. Only those volumes that were mounted by this 
invocation of the MOUNT command are listed. If the volume set name is 
not available, the string "name n/a" appears as the name of 
the volume set.
User Action: Take action based on the accompanying 
message and reenter the MOUNT command.
DISMPART, some of the volumes have been dismounted
Facility: MOUNT, Mount Utility
Explanation: Some of the volumes that were mounted by 
this invocation of the Mount utility or the MOUNT command have been 
dismounted due to errors detected after the volumes were mounted.
User Action: Take action based on the preceding 
messages, and reenter the MOUNT command.
DISRECONNECT, you are not authorized to do reconnections
Facility: LOGIN, Login Procedure
Explanation: Authorization is needed to reconnect to 
disconnected processes.
User Action: Log in again without specifying the 
/CONNECT qualifier after your user name.
DISUSER, account is disabled
Facility: LOGIN, Login Procedure
Explanation: An attempt is made to log in to an 
account when the account is disabled. An account's system access can be 
restricted by setting the DISUSER flag in the user authorization file. 
This message is written to the system accounting and security audit 
records; the NOTVALID message displays to the user.
User Action: None.
DOSETVOL, Use SET VOLUME/STRUCTURE_LEVEL and remount.
Facility: MOUNT, Mount Utility
Explanation: This message accompanies the INCONSTRUCT 
and INCONSET error messages to provide instructions for making the 
volume or volume set consistent.
User Action: If the volume or volume set is not 
currently mounted /NOSHARE, dismount the portion that is currently 
mounted and mount the volume or volume set using /NOSHARE. Then execute 
the DCL command SET VOLUME /STRUCTURE_LEVEL=5 on the volume or volume 
set. Afterwards, you can dismount the volume or volume set and mount it 
as you wish.
DOUBLDALOC, double deallocation of swap file space
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DOUBLDEALO, double deallocation of memory block
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an 
irrecoverable, inconsistent condition. After all physical memory is 
written to a system dump file, the system automatically reboots if the 
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the  /IGNORE=NOBACKUP qualifier to make a backup save set of the  system dump file and the error log file active at the time of the  error. Contact a Compaq support representative and describe the conditions  leading to the error.
DRIVENAM, driver name is 'driver-name'
Facility: SYSGEN, System Generation Utility
Explanation: This message is issued with the message 
SYSVERDIF to identify the driver.
User Action: See the SYSGEN message SYSVERDIF for user 
action information.
DRVERR, fatal drive error
Facility: MOUNT, Mount Utility
Explanation: In a SCSI OpenVMS Cluster environment, a 
request has been made to mount a device on a shared SCSI bus and the 
device does not support SCSI-2 tagged command queuing (TCQ).
User Action: If you want to mount a device on a shared 
SCSI bus, the device must support TCQ.
DSSI Terminator Power failure, possible blown fuse.
Facility: Cluster Port Driver
Explanation: The adapter has detected a hardware 
problem.
User Action: Check the terminator fuse. If it is 
blown, replace it or contact a Compaq support representative to check the DSSI hardware.
DUALLOC, dual allocation on volume 'n'
Facility: RBLD, REBUILD Command (Mount Utility)
Explanation: A logical block on the specified relative 
volume is allocated to more than one file.
User Action: Execute the DCL command 
ANALYZE/DISK_STRUCTURE/NOREPAIR for the volume. This command invokes 
the Analyze/Disk_Structure utility, which issues a message for each 
case of dual file allocation. Each message identifies the file name, 
the range of logical block numbers that are allocated, and the virtual 
block numbers that map to the logical blocks.
After you determine the files involved in each case of dual allocation, 
disallow any other file activity for them and copy all but one file to 
a new version. Then delete the versions containing dual allocation. 
This causes blocks that are not actually free to be marked as free 
blocks in the storage bit map.
Finally, reexecute the ANALYZE/DISK_STRUCTURE/REPAIR command. Then 
examine each file and reconstruct from backup media any files that have 
been corrupted.
Dump aborted, page tables may be corrupted
Facility: BUGCHECK, System Bugcheck
Explanation: When writing a selective dump (SYSGEN 
parameter DUMPSTYLE set to 1), the OpenVMS operating system relies 
heavily on the integrity of the various system and process page tables. 
This message indicates that the system might have detected corruption 
in these page tables, and it will abort further dumping. You might not 
be able to analyze the dump.
User Action: Contact a Compaq support representative.
DUPDEVSPC, duplicate device specified
Facility: MOUNT, Mount Utility
Explanation: The same tape device is specified more 
than once in a list of tape devices for the DCL command MOUNT.
User Action: Reenter the MOUNT command, specifying 
each device only once.
DUPLABEL, duplicate label 'label' not allowed with /EXACT_ORDER 
qualifier
Facility: BACKUP, Backup Utility
Explanation: Duplicate labels cannot be specified with 
the /EXACT_ORDER qualifier. The specified label matches a label that 
was entered previously.
User Action: Reenter the command, specifying unique 
labels.
DUPLICATE_ID, Device 'device-name' has the same ID as a previous device 
for this bus, at line 'line-number'.
Facility: READ_CONFIG, File-Based Autoconfiguration
Explanation: Another device defined earlier in the 
file has the same ID and ADAPTER values. The initial occurrence in the 
file will be used; the second device will be ignored.
User Action: Check your configuration files for 
duplicate records.
DUPOPT, previously specified callable interface option type invalid, 
argument position 'position', option type = 'option-type'
Facility: BACKUP, Backup Utility
Explanation: An option type is specified more than 
once in the set of options. It is illegal to specify duplicates for 
this option type.
User Action: Note the value of the option type found 
and its relative position in the set of options specified to the BACKUP 
API; then remove redundant specifications of this option type. (Refer 
to the BACKUP documentation and the BACKUP API definitions files for 
valid option values.)
DUPRVN, duplicate volume number already mounted
Facility: MOUNT, Mount Utility
Explanation: A volume of the same relative volume 
number and the same volume set name is already mounted. An attempt is 
being made to mount a volume that belongs to a volume set with the same 
name as a volume set that is already mounted.
User Action: Make sure that the correct volume has 
been mounted. Verify that the volume status (/SHARE, /NOSHARE, /GROUP, 
or /SYSTEM) is defined consistently with volumes already mounted.
DUPVOLNAM, volume label already present in set
Facility: MOUNT, Mount Utility
Explanation: During an attempt to add a volume to an 
existing volume set, the specified volume set is found to contain a 
volume with the label specified.
User Action: Verify the labels on the existing volumes 
in the set. Choose a new label for the volume you are adding to the 
set, reinitialize the volume, and reenter the DCL command MOUNT/BIND.
DZRO_ISD, image contains demand zero sections
Facility: LOADER, Executive Image Loader
Explanation: A load request was made for an executive 
image that illegally contains demand zero sections.
User Action: Correct the link procedure used to build 
the executive image; specify the appropriate PSECT_ATTR and COLLECT 