From: JF Mezei [jfmezei.spamnot@videotron.ca] Sent: Monday, March 26, 2001 9:47 PM To: Info-VAX@Mvb.Saic.Com Subject: Re: MicroVax II problem re: console output not seen. Have your tested you console "terminal" with another microvax II to ensure that your "terminal" provides the right modem controls to allow the data to flow properly ? Looking at the console module (the module with the battery, switches and display:. The console port 5 4 3 2 1 9 8 7 6 The ribbon connector (black, small) (J3) 1 2 3 4 5 6 7 . 8 9 1 is ground 2 goes to the cpu board through j3-7 3 goes to the language selection switch and then to J3-4 unless language selection switch is at the T 4 is not connected 5 goes to speed selection switch, but after that, no direct connection 6 is not connected 7 goes to cpu via J3-8 8 goes to cpu via a resistor and then J3-8 (yes, the same as pin 7 !) 9 isn't conected Isn't it unlikely that a serial chip would fail only partially ? If a chip fails, isn't it more likelt that it will fail completly ? I suspect wiring problems.